    With the explosive development of modern industry, global energy demand is increasing. Non renewable energy is drying up. Energy saving and consumption reduction is a common problem faced by all countries at this stage. With the development of frequency conversion technology is becoming more and more mature, widely used in all walks of life using energy-saving inverter technology, compared with the traditional fixed frequency control, frequency conversion control mode of low energy consumption, simple operation, easy maintenance, creating conditions for engine cooling with variable frequency energy saving scheme, to open the market.

    In the past, the ship's cooling water pump and the engine room fan were all fully loaded at full speed according to the design, but in fact, many ships Often run at lower cruising speed, so the system running in the light load state resulting in water pump, valve, fan and wasted a lot of energy. In recent years, many cases show that the transformation through the installation of frequency conversion on the cooling water pump control system can realize the power saving of 50~80%.


    Renergy low THD sea water pump VFD control system


    1.Product overview

    By the sharp low harmonic frequency conversion control of seawater manufacturing products using Fondants pump application converter, SIEMENS PLC S7-1200 and HMI, operation control, real-time monitoring of the whole system, the use of PID control logic in the PLC, the actual flow rate requirements, according to the load condition of the timely adjustment of the pump speed of the host, to ensure that fresh water outflow temperature central cooler the control at 36~38 DEG C, safe and effective energy saving, effectively protect the host pump operation. The typical investment recovery time of the seawater cooling system optimized by frequency converter is about 12 months.

    2. Control system
    There is a master switch system in the control cabinet to control three pumps, each of which has three state positions.
    Manual stop automatic mode
    1# and 2# inverter can be used as the main driver of the system. There are 2 temperature sensors in the system. They are connected to 1# and 2# drivers to meet the redundancy control requirements. The main driver will maintain a constant LT temperature, and control all the pump speeds by master slave cascade. All the pumps in the work run at the same speed, and the system turns three pumps to balance their running time. Renergy provides a complete set of system configuration and installation and debugging.


    3. Low THD sea water pump VFD control product standard parameters.

     Standard Table                  380V-480V    50/60HZ    Air  cooled     IP44


    Item

    Pump motor  capabilitykw


    Type

    Dimension (mm)

    Weight

    kg


    Rules

    W

    H

    D

    1

    30

    RE-ESS30

    1800

    2000

    600

    450

    ALL

    2

    55

    RE-ESS55

    2100

    2000

    600

    520

    ALL

    3

    75

    RE-ESS75

    2200

    2000

    600

    710

    ALL

    4

    90

    RE-ESS90

    2200

    2000

    600

    710

    ALL

    5

    120

    RE-ESS120

    2500

    2000

    800

    100

    ALL

    6

    160

    RE-ESS160

    2500

    2000

    800

    1150

    ALL


    4. Product advantages
    >  energy saving, adopting frequency conversion control method, compared with traditional fixed frequency method to save 40% of the system, reduce greenhouse gas emission;
    >  is simple to operate and easy to maintain;
    >  is easy to transform, with short transformation time, low input cost and high rate of return.
    >  startup current is low, effective protection pump life;
    >  harmonic design, the whole system is reduced within 5% at run time, preventing damage to other equipment on the power grid;
    >  safe and reliable, redundancy design, USES the amphibious a prepared plan, prevent in the case of a frequency converter fault, in a timely manner to enable the standby pump operation, ensure the satisfaction of the cooling water flow rate, according to the requirements of water temperature and the working condition of the host used timely and automatically adjust the number of running pumps, to achieve energy saving purpose;

    >  Bypass Bypass is used to increase the Bypass selection of the frequency converter, so as to prevent the frequency converter from being damaged, Bypass the frequency converter to run the system and ensure the continuous and reliable operation of the system;


    Case analysis:
    Design temperature: 32 ℃
    The actual temperature: 20 ℃
    Run hours (per year) : 6000.
    Electric power cost per KW/h: €0.1.
    Unoptimized system energy consumption: 75KW=450.000KWh/ year.
    Optimized system energy consumption: 14KW=84.000KWh/ year.
    Energy saving: 80%
    Annual cost savings: 36,000.
    Installation of variable frequency system cost:   32,000.
    Investment recovery time: less than 12 months.


    Payback amount for 2 year operation with installed

    Motor(kW)           =No. Of operating Pump*Pump(kW)

    Motor(HP)           =Motor(kW) / 0.746(kW/HP)

    Fuel Consumption(kg/hr)  =Fuel Consumption(kg/HP*hr)*Motor(HP)

    Fuel Consumption(US$/hr)  =Fuel Consumption(kg/hr)*Fuel Cost(US$/kg)

    Daily Cost for Fuel(US$/day)=Fuel Cost(US$/hr)*24hr

    Annual Cost for Fuel(US$/year)=Daily Fuel Cost (US$/day)*Operating Day(day)

    Annual Saving Cost(US$) =Annual Fuel Cost without ESS(US$)-Annual Fuel Cost with ESS(US$)

    Tags:

    BackNext

Please Leave Your Message:

About Us
Renergy Overseas Limited
1-2 Floors of Building 6, 668 Heng'an Road,  Pudong
(86)-021-31347980 31347981
(86)-021-31347985
Core Technology
New space vector technology
Special software dead zone compensation
Excellent speed tracking self-starter with no speed sensor
Automatic energy saving operation
Voltage fluctuation suppression
Friendly human-machine interface with flexible input and output interface
Dc power supply, save the security power investment.
Perfect protection function
Solution & Product
Low THD sea water pump VFD control system
RE-S series motor control cabinet
Propulsion Control System
Optimum Solutions for Pump Drive Systems
Frequency Controlled Drive System
Energy storage and clean energy
Motors
Generators
Sales Performance
600KN电动绞车变频控制

1200KW变频控制柜

128KW脱硫变频控制系统

475KW Thruster VFD Control System

5800 ton MPV multipurpose ship

COSL 6500HP PSV / Oil field Guardians

Copyright © 2018 Renergy Overseas Limited ICP: 14018213  Web Design